IH type pump used in chemical, petroleum, metallurgy, electric power, food, pharmaceutical, synthetic fiber industry sector transport corrosive or do not allow pollution medium, can satisfy the chemical process in the transport of corrosive viscosity similar to water liquid.
Features
● ISO2858-1975(E) is used for rated performance and size of pump.
The cavity size of mechanical seal and soft packing shall be ISO3069-1974(E).
● The rear door opening structure can disassemble the rotor components for maintenance without disassembling the pipeline system.
● The pump outlet and its pipeline are located directly above the middle of the pump foot, and the pump body is evenly stressed, with low vibration and low noise.
Performance range
Flow rate:Q = 6.3 ~ 460m ³/h
Head: H = 11~132m
Conveying medium temperature: t =-20~105 ℃
Model Description

Conveying medium
Various concentrations of sulfuric acid, nitric acid, hydrochloric acid and phosphoric acid and other organic and inorganic acids.
Various concentrations of sodium hydroxide and sodium carbonate and other alkaline solutions, salt solution.
Various liquid petrochemicals, organic compounds, and other corrosive raw materials and products.
Steering of pump
The rotation is clockwise as viewed from the prime mover to the pump.
Performance Parameters of Type IH Corrosion Resistant Pump
| Pump type | Flow rate Q (m³/h) |
head H (m) |
Rotational speed n (r/min) |
power (kW) |
efficiency η (%) |
Cavitation allowance (NPSH)r (m) |
|
| Shaft power | Motor power | ||||||
| IH50-32-125 | 12.5 | 20 | 2900 | 1.33 | 2.2 | 51 | 2.0 |
| IH50-32-125A | 10.8 | 15 | 2900 | 0.86 | 1.5 | ||
| IH50-32-160 | 12.5 | 32 | 2900 | 2.37 | 3 | 46 | 2.0 |
| IH50-32-160A | 11 | 25 | 2900 | 1.62 | 2.2 | ||
| IH50-32-200 | 12.5 | 50 | 2900 | 4.36 | 5.5 | 39 | 2.0 |
| IH50-32-200A | 11.2 | 40 | 2900 | 3.14 | 4 | ||
| IH50-32-250 | 12.5 | 80 | 2900 | 8.25 | 11 | 33 | 2.0 |
| IH50-32-250A | 11.7 | 70 | 2900 | 6.77 | 11 | ||
| IH50-32-250B | 10.8 | 60 | 2900 | 5.32 | 7.5 | ||
| IH65-50-125 | 25 | 20 | 2900 | 2.2 | 3 | 62 | 2.0 |
| IH65-50-125A | 21.6 | 15 | 2900 | 1.42 | 2.2 | ||
| IH65-50-160 | 25 | 32 | 2900 | 3.82 | 5.5 | 57 | 2.0 |
| IH65-50-160A | 22 | 25 | 2900 | 2.6 | 4 | ||
| IH65-40-200 | 25 | 50 | 2900 | 6.55 | 11 | 52 | 2.0 |
| IH65-40-200A | 22.4 | 40 | 2900 | 4.71 | 7.5 | ||
| IH65-40-250 | 25 | 80 | 2900 | 11.84 | 15 | 46 | |
| IH65-40-250A | 23.4 | 70 | 2900 | 9.73 | 15 | ||
| IH65-40-250B | 21 | 60 | 2900 | 7.74 | 11 | ||
| IH65-40-315 | 25 | 125 | 2900 | 21.8 | 30 | 39 | 2.0 |
| IH65-40-315A | 23.5 | 110 | 2900 | 18.1 | 22 | ||
| IH65-40-315B | 22.4 | 100 | 2900 | 15.7 | 22 | ||
| IH65-40-315C | 21.2 | 90 | 2900 | 13.3 | 18.5 | ||
| IH80-65-125 | 50 | 20 | 2900 | 3.95 | 5.5 | 69 | 3.0 |
| IH80-65-125A | 43.3 | 15 | 2900 | 2.57 | 4 | ||
| IH80-65-160 | 50 | 32 | 2900 | 6.5 | 11 | 67 | 2.3 |
| IH80-65-160A | 44.2 | 25 | 2900 | 4.49 | 7.5 | ||
| IH80-50-200 | 50 | 50 | 2900 | 10.8 | 15 | 63 | 2.5 |
| IH80-50-200A | 44.7 | 40 | 2900 | 7.72 | 11 | ||
| IH80-50-250 | 50 | 80 | 2900 | 19.1 | 30 | 57 | 2.6 |
| IH80-50-250A | 46.8 | 70 | 2900 | 15.7 | 22 | ||
| IH80-50-250B | 43.3 | 60 | 2900 | 14 | 18.5 | ||
| IH80-50-315 | 50 | 125 | 2900 | 34 | 45 | 50 | 2.8 |
| IH80-50-315A | 46.9 | 110 | 2900 | 28 | 37 | ||
| IH80-50-315B | 44.7 | 100 | 2900 | 24.3 | 30 | ||
| IH80-50-315C | 42.4 | 90 | 2900 | 20.7 | 30 | ||
| IH100-80-125 | 100 | 20 | 2900 | 7.46 | 11 | 73 | 4.2 |
| IH100-80-125A | 86 | 15 | 2900 | 4.84 | 7.5 | ||
| IH100-80-160 | 100 | 32 | 2900 | 11.9 | 15 | 73 | 4.3 |
| IH100-80-160A | 88.4 | 25 | 2900 | 8.22 | 11 | ||
| IH100-65-200 | 100 | 50 | 2900 | 18.9 | 22 | 72 | 3.9 |
| IH100-65-200A | 89.8 | 40 | 2900 | 13.5 | 18.5 | ||
| IH100-65-250 | 100 | 80 | 2900 | 32.0 | 45 | 68 | 3.6 |
| IH100-65-250A | 93.5 | 70 | 2900 | 26.2 | 37 | ||
| IH100-65-250B | 86.6 | 60 | 2900 | 20.8 | 30 | ||
| IH100-65-315 | 100 | 125 | 2900 | 54.9 | 75 | 62 | 3.2 |
| IH100-65-315A | 93.8 | 110 | 2900 | 45.3 | 55 | ||
| IH100-65-315B | 89.4 | 100 | 2900 | 39.2 | 55 | ||
| IH100-65-315C | 84.9 | 90 | 2900 | 33.6 | 45 | ||
| IH125-100-200 | 200 | 50 | 2900 | 35.4 | 45 | 77 | 5.0 |
| IH125-100-200A | 178.9 | 40 | 2900 | 25.3 | 37 | ||
| IH125-100-250 | 200 | 80 | 2900 | 58.1 | 75 | 75 | 4.5 |
| IH125-100-250A | 187.1 | 70 | 2900 | 47.6 | 75 | ||
| IH125-100-250B | 173.2 | 60 | 2900 | 37.7 | 55 | ||
| IH125-100-315 | 200 | 125 | 2900 | 95.9 | 132 | 71 | 4.0 |
| IH125-100-315A | 187.6 | 110 | 2900 | 79.1 | 110 | ||
| IH125-100-315B | 178.9 | 100 | 2900 | 68.6 | 90 | ||
| IH125-100-315C | 169.7 | 90 | 2900 | 58.6 | 75 | ||
| IH125-100-400 | 100 | 50 | 1450 | 22.3 | 30 | 61 | 3.5 |
| IH125-100-400A | 89.4 | 40 | 1450 | 15.9 | 22 | ||
| IH150-125-250 | 200 | 20 | 1450 | 14.1 | 18.5 | 77 | 2.8 |
| IH150-125-250A | 173.2 | 15 | 1450 | 9.16 | 15 | ||
| IH150-125-315 | 200 |
32.0 |
1450 | 23.2 | 30 | 75 | 2.8 |
| IH150-125-315A | 178.9 | 25 | 1450 | 16 | 22 | ||
| IH150-125-400 | 200 | 50 | 1450 | 38.9 | 55 | 70 | 2.5 |
| IH150-125-400A | 178.9 | 40 | 1450 | 27.8 | 45 | ||
| IH200-150-250 | 400 | 20 | 1450 | 27.2 | 37 | 80 | 3.5 |
| IH200-150-250A | 346.4 | 15 | 1450 | 17.7 | 30 | ||
| IH200-150-315 | 400 | 32 | 1450 | 44.1 | 55 | 79 | 3.5 |
| IH200-150-315A | 353.6 | 25 | 1450 | 30.5 | 45 | ||
| IH200-150-400 | 400 | 47 | 1450 | 69.8 | 90 | 78 | 3.5 |
| IH200-150-400A | 357.8 | 40 | 1450 | 50 | 75 | ||